Euclidean Distance
The original 1976 formula. Simple Euclidean distance in LAB space. Fast but overweights hue differences in some ranges.
ΔE = √(ΔL² + Δa² + Δb²)
Compare any two colors and see their perceptual difference using ΔE76, ΔE94, and CIEDE2000 (ΔE2000).
Measure the perceptual difference between two colors with three industry-standard formulas — ΔE76, ΔE94, and CIEDE2000. See LAB values, per-axis differences, and understand exactly how "close" two colors really are.
Delta E (ΔE) is a numerical measure of how different two colors are in a way that matches human perception. A ΔE of 0 means the colors are identical. As ΔE increases, the colors become increasingly different to the human eye.
Delta E is measured in the CIELAB color space, which was designed to be perceptually uniform — meaning equal distances in LAB correspond to roughly equal perceived differences.
The original 1976 formula. Simple Euclidean distance in LAB space. Fast but overweights hue differences in some ranges.
ΔE = √(ΔL² + Δa² + Δb²)
Introduced in 1994. Weights lightness, chroma, and hue differently — much closer to perceived differences than ΔE76.
ΔE94 = √((ΔL/kL·SL)² + ...)
The current industry standard. Accounts for hue rotation, chroma, and complex lightness correction. Best match to human perception.
ΔE00 with hue rotation + weighting
In professional printing, ΔE values under 2 are generally considered acceptable. Under 1 is "spot on". Anything over 5 will be clearly visible to anyone looking at the two colors side by side.
0 – 1 → Imperceptible
1 – 2 → Very small difference
2 – 5 → Noticeable at close glance
5 – 10 → Clearly different
10 – 20 → Very different
> 20 → Opposite colors
Check that a print matches the proof.
Verify the same brand color across materials.
Ensure dye lots match.
Compare colors across different color spaces.
Measure color drift between shots.
Study perceptual color distances.
Delta E (ΔE) is a numerical measure of how different two colors are, in a way that matches human perception.
CIEDE2000 (ΔE2000) is the most perceptually accurate and is the current industry standard.
For most uses, ΔE under 2 is considered very close. ΔE under 1 is imperceptible. ΔE over 5 is clearly different.
ΔE76 is simple Euclidean distance in LAB. ΔE94 weights lightness, chroma, and hue differently to better match perceived differences.
CIEDE2000 is the most recent and most accurate Delta E formula, used in modern color quality control.
Only if the physical conditions differ (lighting, materials, screen calibration). Under identical viewing conditions, ΔE 0 means identical colors.
No. It converts sRGB to CIELAB using the standard D65 illuminant and computes ΔE formulas with default weightings.
Yes. The Delta E Calculator is completely free.
Delta E gives you a numerical, human-perception-aligned answer to "how different are these colors?" — with three formulas, full LAB breakdown, and instant visual interpretation.